The current Controller Firmware version is V0.06 Build 11


**When updating to version 0.06 Build 11 please open the Parameters tab in PC Tools and click the Retrieve button. Then, browse to the setting for SOG Threshold, change the value to 0, then press the Set button. Failure to follow this procedure may mean that Ditch Assist will not operate the valve unless you are travelling at significant speed!**


The previous version is V0.06 Build 06


The current version as well as the current version of PC Tools can be downloaded from this page


Instructions on how to check installed version and update firmware via laptop/PC can be found here or in the User Manual



Revision History


V0.06 Build 11

26 March 2017

- now recognises NMEA messages starting with GNxxx as well as GPxxx

- use RMC message for speed and direction if VTG not available

- fix for min SOG settings

- SOG setting now set to off by default (enable via PC Tools)


V0.06 Build 06
-------------------------------------------------------------------------------
28 July 2016
- fixed default values for new parameters DOZER_MODE and GPS_BAUD

-------------------------------------------------------------------------------
V0.06 Build 05
-------------------------------------------------------------------------------
25 July 2016
- implemented "stop driving the valve when stationary" logic
- valve is held still if the GPS speed is less 0.2 mph
- valve is driven if cog&sog message is not detected

-------------------------------------------------------------------------------
V0.06 Build 04
-------------------------------------------------------------------------------
18 July 2016
- implemented baud rate setting for NMEA0183 GPS